SECTION
1010 RAMPS
1010.9
Edge protection. Edge protection complying with Sections
1010.9.1 or 1010.9.2 shall be provided on each side of ramp
runs and at each side of ramp landings.
Exceptions:
1. Edge protection is not required on ramps that are not
required to have handrails, provided they have flared
sides that comply with the ICC A117.1 curb ramp provisions.
2.
Edge protection is not required on the sides of ramp landings
serving an adjoining ramp run or stairway.
3. Edge protection is not required on the sides of ramp
landings having a vertical drop off of not more than 0.5
inch (12.7 mm) within 10 inches (254 mm) horizontally
of the required landing area.
1010.9.1 Curb, rail, wall or barrier. A curb, rail,
wall or barrier shall be provided that prevents the passage
of a 4-inch-diameter (102 mm) sphere, where any portion
of the sphere is within 4 inches (102 mm) of the floor or
ground surface.
1010.9.2 Extended floor or ground surface. The floor
or I ground surface of the ramp run or landing shall extend
12 inches (305 mm) minimum beyond the inside face of a handrail
complying with Section 1012.
|
|
|
All
Rights Reserved. This 2006 International Building Code® is a
copyrighted work owned by the International Code Council, Inc. Without
advance written permission from the copyright owner, no part of
this book may be reproduced, distributed, or transmitted in any
form or by any means, including, without limitation, electronic,
optical or mechanical means (by way of example and not limitation,
photocopying, or recording by or in an information storage retrieval
system). For information on permission to copy material exceeding
fair use, please contact: Publications, 4051West Flossmoor Road,
Country Club Hills, IL 60478-5795. Phone 1-888-ICC-SAFE (422-7233).
Trademarks: International Code Council, the International
Code Council logo and the International Building Code
are trademarks of the International Code Council, Inc.
|