SECTION
1020 VERTICAL EXIT ENCLOSURES
1020.1.2
Penetrations. Penetrations into and openings through an
exit enclosure are prohibited except for required exit doors,
equipment and ductwork necessary for independent pressurization,
sprinkler piping, standpipes, electrical raceway for fire
department communication systems and electrical raceway serving
the exit enclosure and terminating at a steel box not exceeding
16 square inches (0.010 m2). Such penetrations
shall be protected in accordance with Section
712. There shall be no penetrations or communication openings,
whether protected or not, between adjacent exit enclosures.
|
|