SECTION
1021 EXIT PASSAGEWAYS
1021.5
Penetrations. Penetrations into and openings through an
exit passageway are prohibited except for required exit doors,
equipment and ductwork necessary for independent pressurization,
sprinkler piping, standpipes, electrical raceway for fire
department communication and electrical raceway serving the
exit passageway and terminating at a steel box not exceeding
16 square inches (0.010 m2). Such penetrations
shall be protected in accordance with Section
712. There shall be no penetrations or communicating openings,
whether protected or not, between adjacent exit passageways.
|
|
All
Rights Reserved. This 2006 International Building Code® is a
copyrighted work owned by the International Code Council, Inc. Without
advance written permission from the copyright owner, no part of
this book may be reproduced, distributed, or transmitted in any
form or by any means, including, without limitation, electronic,
optical or mechanical means (by way of example and not limitation,
photocopying, or recording by or in an information storage retrieval
system). For information on permission to copy material exceeding
fair use, please contact: Publications, 4051West Flossmoor Road,
Country Club Hills, IL 60478-5795. Phone 1-888-ICC-SAFE (422-7233).
Trademarks: International Code Council, the International
Code Council logo and the International Building Code
are trademarks of the International Code Council, Inc.
|