SECTION 1605 LOAD COMBINATIONS
1605.3 Load combinations using
allowable stress design.
1605.3.1 Basic load combinations.
Where allowable stress design (working stress design), as
permitted by this code, is used, structures and portions
thereof shall resist the most critical effects resulting
from the following combinations of loads:
D + F
(Equation 16-8)
D+ H+ F+ L + T
(Equation 16-9)
D+ H+ F+ (Lr or
S or R)
(Equation 16-10)
D + H + F + 0.75(L + T) +
0.75 (Lr or S or R)
(Equation 16-11)
D+ H + F+ (W or 0.7E)
(Equation 16-12)
D + H + F + 0.75(W or 0.7E)
+ 0.75L + 0.75 (Lr or S or R) (Equation
16-13)
0.6D +W +H
(Equation 16-14)
0.6D+ 0.7E+H
(Equation 16-15)
Exceptions:
1.Crane hook loads need not
be combined with roof live load or with more than three-fourths
of the snow load or one-half of the wind load.
2. Flat roof snow loads of
30 psf (1.44 kN/m2) or less need not be combined
with seismic loads. Where flat roof snow loads exceed 30
psf (1.44 kN/m2), 20 percent shall be combined
with seismic loads.
1605.3.1.1 Stress increases.
Increases in allowable stresses specified in the appropriate
material chapter or the referenced standards shall not
be used with the load combinations of Section 1605.3.1,
except that a duration of load increase shall be permitted
in accordance with Chapter 23.
1605.3.1.2 Other loads.
Where Fa is to be considered in design,
the load combinations of Section 2.4.2
of ASCE 7 shall be used.
1605.3.2 Alternative basic
load combinations. In lieu of the basic load combinations
specified in Section 1605.3.1, structures and portions thereof
shall be permitted to be designed for the most critical
effects resulting from the following combinations. When
using these alternative basic load combinations that include
wind or seismic loads, allowable stresses are permitted
to be increased or load combinations reduced where permitted
by the material chapter of this code or the referenced standards.
For load combinations that include the counteracting effects
of dead and wind loads, only two-thirds of the minimum dead
load likely to be in place during a design wind event shall
be used. Where wind loads are calculated in accordance with
Chapter 6 of ASCE 7, the coefficient ω in the following
equations shall be taken as 1.3. For other wind loads, ω
shall be taken as 1. When using these alternative load combinations
to evaluate sliding, overturning and soil bearing at the
soil-structure interface, the reduction of foundation overturning
from Section 12.13.4 in ASCE
7 shall not be used. When using these alternative basic
load combinations for proportioning foundations for loadings,
which include seismic loads, the vertical seismic load effect,
Ev, in Equation 12.4-4 of ASCE 7 is permitted to be taken
equal to zero.
D+ L + (Lr or
S or R)
(Equation 16-16)
D+ L + (ω W)
(Equation 16-17)
D+ L +ω W+ S/2
(Equation 16-18)
D+ L + S +ω W/2
(Equation 16-19)
D+ L + S +E/1.4
(Equation 16-20)
0.9D+E/1.4
(Equation 16-21)
Exceptions:
1. Crane
hook loads need not be combined with roof live loads or
with more than three-fourths of the snow load or one-half
of the wind load.
2. Flat roof snow loads of
30 psf (1.44 kN/m2) or less need not be combined
with seismic loads. Where flat roof snow loads exceed 30
psf (1.44 kN/m2), 20 percent shall be combined
with seismic loads.
1605.3.2.1 Other loads.
Where F, H or T are to be considered in the design, each
applicable load shall be added to the combinations specified
in Section 1605.3.2.
|
|
|
All
Rights Reserved. This 2006 International Building Code® is a
copyrighted work owned by the International Code Council, Inc. Without
advance written permission from the copyright owner, no part of
this book may be reproduced, distributed, or transmitted in any
form or by any means, including, without limitation, electronic,
optical or mechanical means (by way of example and not limitation,
photocopying, or recording by or in an information storage retrieval
system). For information on permission to copy material exceeding
fair use, please contact: Publications, 4051West Flossmoor Road,
Country Club Hills, IL 60478-5795. Phone 1-888-ICC-SAFE (422-7233).
Trademarks: International Code Council, the International
Code Council logo and the International Building Code
are trademarks of the International Code Council, Inc.
|
|