| SECTION 2106 SEISMIC DESIGN
2106.1 Seismic design requirements
for masonry. Masonry structures and components shall comply
with the requirements in Section 1.14.2.2
and Section 1.14.3, 1.14.4,
1.14.5, 1.14.6
or 1.14.7 of ACI 530/ASCE 5/TMS 402
depending on the structures seismic design category
as determined in Section 1613. All masonry walls, unless isolated
on three edges from in-plane motion of the basic structural
systems, shall be considered to be part of the seismic-force-resisting
system. In addition, the following requirements shall be met.
2106.1.1 Basic seismic-force-resisting
system. Buildings relying on masonry shear walls as
part of the basic seismic- force-resisting system shall
comply with Section 1.14.2.2
of ACI 530/ASCE 5/TMS 402 or with Section 2106.1.1.1, 2106.1.1.2
or 2106.1.1.3.
2106.1.1.1 Ordinary plain
prestressed masonry shear walls. Ordinary plain prestressed
masonry shear walls shall comply with the requirements
of Chapter 4 of ACI 530/ASCE 5/TMS 402.
2106.1.1.2 Intermediate
prestressed masonry shear walls. Intermediate prestressed
masonry shear walls shall comply with the requirements
of Section 1.14.2.2.4 of
ACI 530/ASCE 5/TMS 402 and shall be designed by Chapter
4, Section 4.4.3, of ACI 530/ASCE
5/TMS 402 for flexural strength and by Section
3.3.4.1.2 of ACI 530/ASCE 5/TMS 402 for shear strength.
Sections 1.14.2.2.5, 3.3.3.5
and 3.3.4.3.2(c) of ACI 530/ASCE
5/TMS 402 shall be applicable for reinforcement. Flexural
elements subjected to load reversals shall be symmetrically
reinforced. The nominal moment strength at any section
along a member shall not be less than one-fourth the maximum
moment strength. The cross-sectional area of bonded tendons
shall be considered to contribute to the minimum reinforcement
in Section 1.14.2.2.4 of
ACI 530/ASCE 5/TMS 402. Tendons shall be located in cells
that are grouted the full height of the wall.
2106.1.1.3 Special prestressed
masonry shear walls. Special prestressed masonry shear
walls shall comply with the requirements of
Section 1.14.2.2.5 of ACI 530/ASCE 5/TMS 402 and shall
be designed by Chapter 4, Section
4.4.3, of ACI 530/ASCE 5/TMS 402 for flexural strength
and by Section 3.3.4.1.2 of
ACI 530/ASCE 5/TMS 402 for shear strength.
Sections 1.14.2.2.5(a), 3.3.3.5
and 3.3.4.3.2(c) of ACI
530/ASCE 5/TMS 402 shall be applicable for reinforcement.
Flexural elements subjected to load reversals shall be
symmetrically reinforced. The nominal moment strength
at any section along a member shall not be less than one-fourth
the maximum moment strength. The cross-sectional area
of bonded tendons shall be considered to contribute to
the minimum reinforcement in Section
1.14.2.2.5 of ACI 530/ASCE 5/TMS 402.
2106.1.1.3.1 Prestressing
tendons. Prestressing tendons shall consist of bars
conforming to ASTM A 722.
2106.1.1.3.2 Grouting.
All cells of the masonry wall shall be grouted.
2106.2 Anchorage of masonry
walls. Masonry walls shall be anchored to the roof and
floors that provide lateral support for the wall in accordance
with Section 1604.8.2.
2106.3 Seismic Design Category
B. Structures assigned to Seismic Design Category B shall
conform to the requirements of Section
1.14.4 of ACI 530/ASCE 5/TMS 402 and to the additional
requirements of this section.
2106.3.1 Masonry walls not
part of the lateral- force-resisting system. Masonry
partition walls, masonry screen walls and other masonry
elements that are not designed to resist vertical or lateral
loads, other than those induced by their own mass, shall
be isolated from the structure so that the vertical and
lateral forces are not imparted to these elements. Isolation
joints and connectors between these elements and the structure
shall be designed to accommodate the design story drift.
2106.4 Additional requirements
for structures in Seismic Design Category C. Structures
assigned to Seismic Design Category C shall conform to the
requirements of Section 2106.3, Section
1.14.5 of ACI 530/ASCE 5/TMS 402 and the additional requirements
of this section.
2106.4.1 Design of discontinuous
members that are part of the lateral-force-resisting system.
Columns and pilasters that are part of the lateral-force-resisting
system and that support reactions from discontinuous stiff
members such as walls shall be provided with transverse
reinforcement spaced at no more than one-fourth of the least
nominal dimension of the column or pilaster. The minimum
transverse reinforcement ratio shall be 0.0015. Beams supporting
reactions from discontinuous walls or frames shall be provided
with transverse reinforcement spaced at no more than one-half
of the nominal depth of the beam. The minimum transverse
reinforcement ratio shall be 0.0015.
2106.5 Additional requirements
for structures in Seismic Design Category D. Structures
assigned to Seismic Design Category D shall conform to the
requirements of Section 2106.4, Section
1.14.6 of ACI 530/ASCE 5/TMS 402 and the additional requirements
of this section.
2106.5.1 Loads for shear
walls designed by the working stress design method.
When calculating in-plane shear or diagonal tension stresses
by the working stress design method, shear walls that resist
seismic forces shall be designed to resist 1.5 times the
seismic forces required by Chapter 16. The 1.5 multiplier
need not be applied to the overturning moment.
2106.5.2 Shear wall shear
strength. For a shear wall whose nominal shear strength
exceeds the shear corresponding to development of its nominal
flexural strength, two shear regions exist. For all cross
sections within a region defined by the base of the shear
wall and a plane at a distance Lw above the base
of the shear wall, the nominal shear strength shall be determined
by Equation 21-1.
Vn=An
Pn fy
(Equation 21-1)
The required shear strength
for this region shall be calculated at a distance Lw
/2 above the base of the shear wall, but not to exceed one-half
story height. For the other region, the nominal shear strength
of the shear wall shall be determined from Section
2108.
2106.6 Additional requirements
for structures in Seismic Design Category E or F. Structures
assigned to Seismic Design Category E or F shall conform to
the requirements of Section 2106.5 and Section
1.14.7 of ACI 530/ASCE 5/TMS 402.
|