| SECTION 2303 MINIMUM STANDARDS
AND QUALITY
2303.1.8 Preservative-treated
wood. Lumber, timber, plywood, piles and poles supporting
permanent structures required by Section
2304.11 to be preservative treated shall conform to the
requirements of the applicable AWPA Standard U1 and M4 for
the species, product, preservative and end use. Preservatives
shall be listed in Section 4 of AWPA U1. Lumber and plywood
used in wood foundation systems shall conform to Chapter 18.
2303.1.8.1 Identification.
Wood required by Section 2304.11
to be preservative treated shall bear the quality mark of
an inspection agency that maintains continuing supervision,
testing and inspection over the quality of the preservative-treated
wood. Inspection agencies for preservative- treated wood
shall be listed by an accreditation body that complies with
the requirements of the American Lumber Standards Treated
Wood Program, or equivalent. The quality mark shall be on
a stamp or label affixed to the preservative-treated wood,
and shall include the following information:
1. Identification of treating
manufacturer.
2. Type of preservative used.
3. Minimum preservative retention
(pcf).
4. End use for which the
product is treated.
5. AWPA standard to which
the product was treated.
6. Identity of the accredited
inspection agency.
2303.1.8.2 Moisture content.
Where preservative- treated wood is used in enclosed locations
where drying in service cannot readily occur, such wood
shall be at a moisture content of 19 percent or less before
being covered with insulation, interior wall finish, floor
covering or other materials.
|
|
|
All
Rights Reserved. This 2006 International Building Code® is a
copyrighted work owned by the International Code Council, Inc. Without
advance written permission from the copyright owner, no part of
this book may be reproduced, distributed, or transmitted in any
form or by any means, including, without limitation, electronic,
optical or mechanical means (by way of example and not limitation,
photocopying, or recording by or in an information storage retrieval
system). For information on permission to copy material exceeding
fair use, please contact: Publications, 4051West Flossmoor Road,
Country Club Hills, IL 60478-5795. Phone 1-888-ICC-SAFE (422-7233).
Trademarks: International Code Council, the International
Code Council logo and the International Building Code
are trademarks of the International Code Council, Inc.
|
|