2607.1 General. Light-transmitting
plastics shall not be used as wall panels in exterior walls
in occupancies in Groups A-l, A-2, H, I-2 and I-3. In other
groups, light- transmitting plastics shall be permitted to
be used as wall panels in exterior walls, provided that the
walls are not required to have a fire-resistance rating and
the installation conforms to the requirements of this section.
Such panels shall be erected and anchored on a foundation,
waterproofed or otherwise protected from moisture absorption
and sealed with a coat of mastic or other approved waterproof
coating. Light-transmitting plastic wall panels shall also
comply with Section 2606.
2607.2 Installation. Exterior
wall panels installed as provided for herein shall not alter
the type of construction classification of the building.
2607.3 Height limitation.
Light-transmitting plastics shall not be installed more than
75 feet (22 860 mm) above grade plane, except as allowed by
Section 2607.5.
2607.4 Area limitation and
separation. The maximum area of a single wall panel and
minimum vertical and horizontal separation requirements for
exterior light-transmitting plastic wall panels shall be as
provided for in Table 2607.4.
The maximum percentage of wall area of any story in light-transmitting
plastic wall panels shall not exceed that indicated in Table
2607.4 or the percentage of unprotected openings permitted
by Section 704.8, whichever is smaller.
Exceptions:
1. In structures provided with
approved flame barriers extending 30 inches (760 mm) beyond
the exterior wall in the plane of the floor, a vertical
separation is not required at the floor except that provided
by the vertical thickness of the flame barrier projection.
2. Veneers of approved weather-resistant
light-transmitting plastics used as exterior siding in buildings
of Type V construction in compliance with Section
1406.
3. The area of light-transmitting
plastic wall panels in exterior walls of greenhouses shall
be exempt from the area limitations of Table
2607.4 but shall be limited as required for unprotected
openings in accordance with Section
704.8.
2607.5 Automatic sprinkler
system. Where the building is equipped throughout with
an automatic sprinkler system in accordance with Section
903.3.1.1, the maximum percentage area of exterior wall
in any story in light-transmitting plastic wall panels and
the maximum square footage of a single area given in Table
2607.4 shall be increased 100 percent, but the area of
light-transmitting plastic wall panels shall not exceed 50
percent of the wall area in any story, or the area permitted
by Section 704.8 for unprotected openings,
whichever is smaller. These installations shall be exempt
from height limitations.
2607.6 Combinations of glazing
and wall panels. Combinations of light-transmitting plastic
glazing and light-transmitting plastic wall panels shall be
subject to the area, height and percentage limitations and
the separation requirements applicable to the class of light-transmitting
plastic as prescribed for light-transmitting plastic wall
panel installations.
|