| SECTION 408 GROUP 1-3
408.4.1 Remote release.
Remote release of locks on doors in a means of egress shall
be provided with reliable means of operation, remote from
the resident living areas, to release locks on all required
doors. In Occupancy Conditions 3 or 4, the arrangement, accessibility
and security of the release mechanism (s) required for egress
shall be such that with the minimum available staff at any
time, the lock mechanisms are capable of being released within
2 minutes.
Exception: Provisions
for remote locking and unlocking of occupied rooms in Occupancy
Condition 4 are not required provided that not more than 10
locks are necessary to be unlocked in order to move occupants
from one smoke compartment to a refuge area within 3 minutes.
The opening of necessary locks shall be accomplished with
not more than two separate keys.
|
|
|
All
Rights Reserved. This 2006 International Building Code® is a
copyrighted work owned by the International Code Council, Inc. Without
advance written permission from the copyright owner, no part of
this book may be reproduced, distributed, or transmitted in any
form or by any means, including, without limitation, electronic,
optical or mechanical means (by way of example and not limitation,
photocopying, or recording by or in an information storage retrieval
system). For information on permission to copy material exceeding
fair use, please contact: Publications, 4051West Flossmoor Road,
Country Club Hills, IL 60478-5795. Phone 1-888-ICC-SAFE (422-7233).
Trademarks: International Code Council, the International
Code Council logo and the International Building Code
are trademarks of the International Code Council, Inc.
|