SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
[F] 415.6.2.1 Mixed occupancies.
Where the storage tank area is located in a building of two
or more occupancies, and the quantity of liquid exceeds the
maximum allowable quantity for one control area, the use shall
be completely separated from adjacent fire areas in accordance
with the requirements of Section 508.3.3.
[F] 415.6.2.1.1
Height exception. Where storage tanks are located within
only a single-story building, the height limitation of Section
503 shall not apply for Group H.
|
|