For SI: 1 inch
= 25.4 mm, 1 square foot = 0.0929m2.
a. Class C interior finish materials shall be permitted
for wainscotting or paneling of not more than 1,000 square
feet of applied surface area in the grade lobby where
applied directly to a noncombustible base or over furring
strips applied to a noncombustible base and fireblocked
as required by Section 803.4.1.
b. In exit enclosures of buildings less than three stories
in height of other than Group I-3, Class B interior finish
for nonsprinklered buildings and Class C interior finish
for sprinklered buildings shall be permitted.
c. Requirements for rooms and enclosed spaces shall be
based upon spaces enclosed by partitions. Where a fire-resistance
rating is required for structural elements, the enclosing
partitions shall extend from the floor to the ceiling.
Partitions that do not comply with this shall be considered
enclosing spaces and the rooms or spaces on both sides
shall be considered one. In determining the applicable
requirements for rooms and enclosed spaces, the specific
occupancy thereof shall be the governing factor regardless
of the group classification of the building or structure.
d. Lobby areas in Group A-1, A-2 and A-3 occupancies shall
not be less than Class B materials.
e. Class C interior finish materials shall be permitted
in places of assembly with an occupant load of 300 persons
or less.
f. For places of religious worship, wood used for ornamental
purposes, trusses, paneling or chancel furnishing shall
be permitted.
g. Class B material is required where the building exceeds
two stories.
h. Class C interior finish materials shall be permitted
in administrative spaces.
i. Class C interior finish materials shall be permitted
in rooms with a capacity of four persons or less.
j. Class B materials shall be permitted as wainscotting
extending not more than 48 inches above the finished floor
in corridors.
k. Finish materials as provided for in other sections
of this code.
l. Applies when the exit enclosures, exit passageways,
corridors or rooms and enclosed spaces are protected by
a sprinkler system installed in accordance with Section
903.3.1.1 or 903.3.1.2.
|
|
|
All
Rights Reserved. This 2006 International Building Code® is a
copyrighted work owned by the International Code Council, Inc. Without
advance written permission from the copyright owner, no part of
this book may be reproduced, distributed, or transmitted in any
form or by any means, including, without limitation, electronic,
optical or mechanical means (by way of example and not limitation,
photocopying, or recording by or in an information storage retrieval
system). For information on permission to copy material exceeding
fair use, please contact: Publications, 4051West Flossmoor Road,
Country Club Hills, IL 60478-5795. Phone 1-888-ICC-SAFE (422-7233).
Trademarks: International Code Council, the International
Code Council logo and the International Building Code
are trademarks of the International Code Council, Inc.
|
|